Online shop

Petrol generators

SPARK petrol generators — reliable and affordable electricity

Looking for a powerful, durable and cost-effective source of electricity? SPARK petrol generators offer an outstanding balance of power, reliability and ease of use. They are the ideal solution for home backup power during grid outages, fieldwork on construction sites, agricultural use and powering tools in workshops.

Key features

All SPARK petrol generators are equipped with advanced AVR voltage stabilisation, which protects connected devices from current fluctuations. You can choose between single-phase (230 V) and three-phase (400 V) models, with manual or convenient electric start and the option of automatic transfer (ATS).

In stock
3.5 kW

SPARK 4500i

1,045.00 € incl. 22% VAT

Voltage
230 V
Max. power
3.8 kW
Rated power
3.5 kW
Engine start
Manual + electric (push-button)
Sockets
2× 5 V USB-A, 1× DC 12 V/9 A car socket, 2× Schuko 230 V/16 A
In stock
5.5 kW

SPARK 6000iA

1,570.00 € incl. 22% VAT

Voltage
230 V
Max. power
6 kW
Rated power
5.5 kW
Engine start
Manual + electric (push-button)
Sockets
2× 5 V USB-A, 1× DC 12 V/9 A car socket, 1× Schuko 230 V/16 A, 1× 3P 230 V/32 A

Buying guide:How to choose the right SPARK petrol generator?

Choosing the right petrol generator depends on the types and total power of the loads you intend to power. Unlike diesel or inverter units, classic petrol generators offer the highest starting power per euro invested, which is key for powering demanding power tools and machinery.

Comparative analysis:Petrol generators compared with other technologies

More = better

This category

Petrol generators

Investment cost
Low — the best price for the power available.
Starting at low temperatures
Excellent — reliable starting even in winter.
Noise and weight
Moderate weight, standard noise level.
Intended use
Construction sites, workshops, home backup power.
Voltage regulation
AVR (Automatic Voltage Regulator).
Products on this page

Diesel generators

Investment cost
High — a higher initial investment.
Starting at low temperatures
Difficult at temperatures below 0 °C.
Noise and weight
Heavier and louder models.
Intended use
Industry, continuous operation (24/7).
Voltage regulation
AVR or AVR + digital module.
Diesel generators

Inverter generators

Investment cost
Medium to high.
Starting at low temperatures
Reliable.
Noise and weight
Exceptionally quiet and light to transport.
Intended use
Camping, sensitive electronics, TVs, computers.
Voltage regulation
Pure sine wave (microprocessor).
Inverter generators

Detailed comparison ofSPARK petrol generator types

Single-phase (230 V) or three-phase (400 V) generator?

Single-phase generators (230 V)

The generator's full power is available at the 230 V sockets. The perfect choice for most households, single-phase tools, mixers and lighting.

Three-phase generators (400 V)

Intended exclusively for running genuine 3-phase loads (e.g. industrial compressors, larger saws, 400 V pumps).

The most common mistake when buying is choosing a three-phase generator to power single-phase loads. With a three-phase generator, the total rated power is split across three equal phases. If you have a 6,000 W three-phase generator, only 2,000 W of power is available at any single standard 230 V socket.

Open-frame or silent (enclosed) generator?

Open-frame generators

They provide optimum air cooling of the engine, outstanding robustness and easy maintenance. The perfect choice for construction sites and fieldwork.

Soundproof generators

Built into an enclosed housing that drastically reduces noise. Suitable for built-up residential areas and zones with noise restrictions.

Silent generators

Manual or electric start?

Manual start (recoil)

Simple, reliable and independent of battery condition.

Electric start (key or button)

Lets you start the engine without physical effort. Models with electric start also allow you to connect an ATS automatic switch, which automatically detects a mains power failure and starts the generator.

Generators with ATS

Not sure which model suits your appliances?

Calculate the power you need or consult our engineering team — we will help you choose the right size and configuration of generator.

FAQ

Frequently asked questions

The main difference lies in how the electricity is produced. A classic petrol generator runs at a constant speed (3,000 rpm) and uses an AVR system to regulate voltage. An inverter generator, on the other hand, converts the energy it produces into direct current and then back into alternating current with a pure sine wave. Inverter models are quieter and more economical, while classic petrol generators offer significantly higher starting power for a lower price.

AVR (Automatic Voltage Regulator) is an electronic system for automatic voltage regulation. It automatically maintains a stable output voltage (230 V or 400 V) regardless of fluctuations in load or engine speed. This protects connected tools and household appliances from dangerous voltage surges.

SPARK petrol generators with a built-in AVR system can safely power most standard household appliances and tools. However, for highly sensitive microprocessor electronics, smart TVs, medical equipment or heat pumps, we always recommend SPARK inverter generators, which deliver a 100% pure sine wave.

Inverter generators

To calculate it, add up the running power (W) of all the devices you want to power at the same time.

Important: for devices with electric motors (e.g. submersible pumps, compressors, refrigerators, angle grinders), you must multiply the running power by the starting current factor — usually 2× to 3× the running power, as these devices draw significantly more energy when starting.

Use the power calculator

SPARK generators run on unleaded petrol (Eurosuper 95 / E5 or E10). The 4-stroke engine is lubricated with a quality SAE 10W-30 or SAE 10W-40 engine oil. Before the first start, you must top up the oil to the marked level, as the generators have a built-in safety switch that prevents starting when the oil level is low.