They are the perfect choice for residential neighbourhoods, holiday homes, camping, outdoor events, restaurant terraces, fieldwork in urban centres and as quiet backup power for homes and businesses. Thanks to soundproof canopies, advanced silencers and anti-vibration dampers, they run considerably more quietly than classic open-frame generators.

In stock
3 kW

SPARK 4000i

575.00 € incl. 22% VAT

Voltage
230 V
Max. power
3.5 kW
Rated power
3 kW
Engine start
Manual
Sockets
1× USB-A 5V and 1x USB-C 5 V, 2× Schuko 230 V/16 A
In stock
3 kW

SPARK 3200i

680.00 € incl. 22% VAT

Voltage
230 V
Max. power
3.2 kW
Rated power
3 kW
Engine start
Manual
Sockets
2× 5 V USB-A, 2× Schuko 230 V/16 A
In stock
4.5 kW

SPARK 7000i

730.00 € incl. 22% VAT

Voltage
230 V
Max. power
4.8 kW
Rated power
4.5 kW
Engine start
Manual + electric (push-button)
Sockets
1× USB-A 5V and 1x USB-C 5 V, 1× Schuko 230 V/16 A, 1× 3P 230 V/32 A
In stock
3 kW

SPARK 3500i

785.00 € incl. 22% VAT

Voltage
230 V
Max. power
3.5 kW
Rated power
3 kW
Engine start
Manual (recoil)
Sockets
1x 5 V USB, 2× Schuko 230 V/16 A
In stock
3.5 kW

SPARK 4500i

1,045.00 € incl. 22% VAT

Voltage
230 V
Max. power
3.8 kW
Rated power
3.5 kW
Engine start
Manual + electric (push-button)
Sockets
2× 5 V USB-A, 1× DC 12 V/9 A car socket, 2× Schuko 230 V/16 A
In stock
6 kW

SPARK 8000iA

1,255.00 € incl. 22% VAT

Voltage
230 V
Max. power
6.5 kW
Rated power
6 kW
Engine start
Manual + electric (push-button)
Sockets
1× USB-A 5V and 1x USB-C 5 V, 1× DC 12 V/9 A car socket, 1× Schuko 230 V/16 A, 1× 3P 230 V/32 A
In stock
5.5 kW

SPARK 6000iA

1,570.00 € incl. 22% VAT

Voltage
230 V
Max. power
6 kW
Rated power
5.5 kW
Engine start
Manual + electric (push-button)
Sockets
2× 5 V USB-A, 1× DC 12 V/9 A car socket, 1× Schuko 230 V/16 A, 1× 3P 230 V/32 A
Out of stock
1.1 kW

SPARK 1200i

Price on request

Voltage
230 V
Max. power
1.2 kW
Rated power
1.1 kW
Engine start
Manual
Sockets
2× 5 V USB-A, 1× Schuko 230 V/16 A

Buying guide:How do silent generators work, and how do you choose the right one?

When choosing a silent generator, the noise level is measured in decibels (dB(A)) at a standard distance of 7 metres. To give you an idea: a standard non-insulated generator produces around 90–95 dB(A) of noise, while SPARK silent inverter and enclosed generators reach exceptionally low noise levels at 50% load (from as little as 59 dB(A)), equivalent to a quiet conversation or household appliances running.

The low noise level is achieved through a combination of three key elements:

Soundproof canopy (Soundproof Enclosure)
Built-in high-density composite insulating foam that absorbs sound waves inside the unit.
Special exhaust silencers
Multi-chamber exhaust systems with silencers that drastically reduce exhaust noise.
Anti-vibration dampers (Silent Block)
Rubber dampers between the engine and the chassis that prevent vibrations being transmitted to the ground and the housing.

Official noise level overview of SPARK silent generators with a soundproof canopy (at 50% load at 7 m)

Here is a detailed overview of the factory-measured noise levels for all soundproof models (Soundproof Enclosure) in the SPARK range:

Petrol silent inverter generators (for light, medium and household use)

Generator model Housing type Noise level: dB(A) @ 7 m (at 50% load) Everyday comparison Suitable for
SPARK 1200i Soundproof
59 dB(A)
Whisper / quiet office Camping, motorhomes, work with light electronics
SPARK 3200i Soundproof
60 dB(A)
Quiet conversation / refrigerator Garden work, small trade jobs
SPARK 4500i Soundproof
62 dB(A)
Normal conversation Home backup power, workshops, holiday homes
SPARK 6000iA Soundproof
62 dB(A)
Normal conversation Larger households, mobile workshops
SPARK 13000iA Soundproof
66 dB(A)
Louder conversation Powerful backup power for larger houses
SPARK 15000iA Soundproof
69 dB(A)
Louder conversation Powerful backup power for demanding buildings

Diesel industrial soundproof generators (for demanding buildings and industry)

Generator model Housing type Noise level: dB(A) @ 7 m (at 50% load) Suitable for
SPARK 9000DiA Soundproof
70 dB(A)
Home backup power, holiday homes, smaller farms
SPARK 10000DiA Soundproof
70 dB(A)
Home backup power, farms, fieldwork
SPARK 27BD Soundproof
69,2 dB(A)
Trade workshops, farms
SPARK 55BD Soundproof
70,8 dB(A)
Industry, commercial buildings, larger farms
SPARK 90BD Soundproof
72 dB(A)
Industrial companies, construction sites in city centres
SPARK 110BD Soundproof
72,2 dB(A)
Larger industrial facilities
SPARK 165BD Soundproof
74,3 dB(A)
Large industrial complexes
SPARK 275BD Soundproof
75 dB(A)
Very large industrial and infrastructure systems
Important noteSoundproofing levels of industrial generators

In addition to standard sound insulation (Silent / Soundproof), shown in the table above, industrial practice recognises two more advanced levels of noise attenuation for specific environments:

Super Silent

Generators with double sound insulation of the housing and additionally attenuated air ducts, for areas where stricter noise limits apply (residential neighbourhoods, night-time events).

Medical Grade Super Silent

The highest level of sound insulation, in which a standard soundproofed generator is placed in an additional, larger insulated container and fitted with a special super-silent, physically much larger exhaust silencer. Such systems are used at critical locations such as hospitals, health centre complexes, recording studios and sites with zero tolerance for noise.

Service insight:Sound insulation means a greater need for proper cooling!

Silent generators offer exceptional comfort, but a soundproof enclosed housing brings specific operating requirements that our service team draws attention to:

Heat stays trapped – do not enclose the generator in additional spaces!

Because the generator is already enclosed in a soundproof housing, high temperatures build up inside it during operation. The air ducts in the housing are precisely sized to draw in cool air and expel hot air. Never enclose a silent generator further in small unventilated boxes, sheds or cabinets, as this will prevent air circulation, leading to rapid overheating of the electronics or engine seizure.

Two types of silent generatorsPetrol inverter vs. encapsulated diesel

Petrol inverter silent generators: Extremely light, compact and quiet. Ideal for light to medium loads (camping, weekend homes, laptops, occasional backup power).

Diesel soundproof generators (fully enclosed): Heavier, more robust generators on a chassis. Suitable for larger loads, all-day operation and permanent backup power for houses, farms or construction sites in urban areas.

Correct placement for minimal noise and many years of operation

For the lowest noise level and for safety, place a generator of suitable size on a level, dry and firm surface. The air inlet and outlet openings must be at least 1 to 1.5 metres from the nearest wall or obstacle.

Not sure which model suits your appliances?

Calculate the power you need or consult our engineering team — we will help you choose the right size and configuration of generator.

FAQ

Frequently asked questions

The decibel scale is logarithmic – a noise reduction of 10 dB halves the perceived loudness. A standard open-frame generator produces around 90–95 dB(A), while SPARK silent enclosed generators run at 59–75 dB(A) at 50% load. In practice, this means silent generators are up to 4 times quieter than conventional open-frame generators.

No! Despite their low noise level, silent generators still use an internal combustion engine, which produces a deadly and dangerous gas – carbon monoxide (CO) – as well as a large amount of heat. Silent generators must always run outdoors or in a purpose-designed engine room with exhaust gas extraction and a fresh air supply.

Modern SPARK silent generators have advanced air ducts and built-in fans that ensure optimal cooling inside the canopy. Overheating only occurs if the user covers the air openings, places the generator right next to a wall or encloses it in a small makeshift box with no airflow.

On silent inverter generators, the Smart Throttle system automatically reduces engine speed when the connected devices do not need full power. When the load is lower (e.g. only lights or a phone charger connected), the generator runs at extremely low revs, which means near-silent operation (from 59 dB(A)) and minimal fuel consumption.

Inverter generators

Yes, silent generators are the most popular choice for houses in densely built-up neighbourhoods. During a power cut they can also run at night without disturbing your sleep or your neighbours.

Generators with ATS